Hydrology Water Level
Ultrasonic Level Transducer
The TLU is a non-contact instrument. Furthermore, it allows to speed up and simplify the installation and maintenance steps. The sensor is supplied complete with power and signal cable (12m).
Range | 0,6 ÷ 8 m ; 0,8÷ 16 m |
Accuracy | ± 1 cm |
Sensitivity | 0,5 cm |
Transducer | Piezoelectric |
Working temperature | -20 ÷ 65 °C |

Radar Level Transducer
The measuring principle is not affected by variations in atmospheric temperature and by suspended dust between the sensor and the measured surface, ensuring the acquisition of a reliable data even in extreme environmental conditions. The measurement principle is based above the emission of a radar impulse in the direction of the surface of interest and on the subsequent reception of the reflected wave. The distance between the sensor and the measuring surface is calculated from the signal time of flight.
The TLR is a non-contact instrument. Furthermore, it allows to speed up and simplify the installation and maintenance steps. The sensor is available with the digital outputs SDI12 and RS485, or 4-20 mA, and is supplied with power and signal cable (12m).
Range | TLR3 : 30 meters TLR4 : 40 meters |
Accuracy | ± 2 mm |
Resolution | 1 mm |
Transducer | Radar |
Working temperature | -40 ÷ 80 °C |

Conventional Water level sensor
Measure principle: A conventional float system drives an absolute shaft encoder with digital output in Gray code(25 bits). A microprocessor based electronic module provides different outputs proportional to the hydrometric level.
Intelligent sensor: The transducer belongs to the intelligent sensor family and allows, among other functions, the correct control functioning, data pre-processing, electrical signal A/D conversion etc. These characteristics warrant excellent accuracy, long-term stability and high data reliability. It can be provided with an interface for data recording on removable memory card which can downloaded by a portable PC or withdrawn for next reading in the office.
Laboratory calibration: The sensor can be supplied with a SIAP+MICROS calibration certificate or with calibration certificates issues by external primary metrological services . Housing materials and International standards: A compact and robust die casting housing grants a IP 67 protection .
Range | -5000 ÷ 5000 mm / 0 ÷ 40000 mm |
Sensitivity | 1 mm |
Transducer | Encoder assoluto digitale |
Working temperature | -30 ÷ 60 °C |